Regolare e distribuire energia pulita
Full bore 2-way zone ball valve, with bidirectional actuator with quick connection. Dimensions from 1/2" DN15 to 1"1/4 DN32.
Product fileMultifunctional compact hydraulic module for the management of a direct circuit, a mixed circuit and the production of domestic hot water (DHW)
Product fileAnti-scald thermostatic mixing valve for medium and small applications. Compact size. Available Kvs: 1.5, 1.8 and 3.4.
Product fileControl unit for manifolds of heating and cooling radiant panels up to 200 m2. Fixed point thermostatic mixer or motorized rotary mixing valve. LCD room control unit.
Product fileModular multi-zone distribution box for wall-mounted gas boilers or heat pumps. Three types of available pump units: direct, mixed motorized, mixed fixed point.
Product fileElegant chrono-thermostat with TFT capacitive touch panel. Wi-Fi N 2.4 Ghz connection for remote control by °Caleon app.
Product file35÷60°C thermostatic mixing kit designed for ModvFresh Basic, with anti-scald thermostatic mixing valve for small applications.
Product fileThe unit for 1” (180 mm) circulating pumps consists of:
SUPPLY:
RETURN:
Centre distance 125 mm. EPP insulation box (Measurements: 250x380x170 mm).
PN 10, max temperature 110°C (unit without pump).
External connections: 1” Female.
![]() |
The By-pass integrated into the 3-way mixing valve ensures a recyling inside the installation, even when the mixing valve is fully open. Through the by-pass, a fixed percent of the mixing can be set, in the case when the flow through the mixing valve is not sufficient. |
Δt | Approximate power and flow of the installation |
Recommended circulating pump |
Residual lifting power |
Approximate surface of the underfloor heating system |
8 K | 17 kW - 1800 l/h | Wilo Yonos Para RS 25/6 | 3 mH2O | Up to 100 m2 |
8 K | 20 kW - 2200 l/h | Wilo Yonos Para RS 25/7,5 | 5 mH2O | Up to 200 m2 |
15 K | 31 kW - 1800 l/h | Wilo Yonos Para RS 25/6 | 3 mH2O | - |
15 K | 38 kW - 2200 l/h | Wilo Yonos Para RS 25/7,58 | 5 mH2O | - |
Working principle |
![]() |
Reference indicator | Reference indicator |
![]() |
![]() |
The By-pass is fully open and it allows the maximum recycling. The screwdriver cut is aligned along the reference indicator. |
The By-pass is fully closed and there is no recycling. The screwdriver cut is in an orthogonal position (at 90°) in comparison with the reference indicator. |
![]() |
MODEL WITH BUILT-IN M21 SERVOMOTOR |
![]() |
MODEL WITH BUILT-IN AHC20 SERVOMOTOR |
![]() |
MODEL WITH BUILT-IN CMP25-2 CLIMATIC CONTROLLER |
M2 MIX33:
Code 1”: 20355R-M33 - with circ. pump: 20355R-M33-(Y6/UL7/Y8)
M2 MIX33 with built-in M21 servomotor:
Code 1”: 20355R-M33-M21 - with circ. pump: 20355R-M33-(Y6/U7/Y8)M21
M2 MIX33 with built-in AHC20 servomotor:
Code 1”: 20355R-M33-AHC - with circ. pump: 20355R-M33-(Y6/U7/Y8)AHC
M2 MIX33 with built-in CMP25-2 climatic controller:
Code 1”: 20355R-M33-CMP - with circ. pump: 20355R-M33-(Y6/U7/Y8)CMP
Note: in units with pre-assembled pump, the pump
Grundfos UPM3 AUTO L 25-70 is identified in the code with U7.
Standard version: right supply.
Left supply version available with extra price: see price list.