BRV Bonetti Rubinetterie Valduggia S.r.l.

MODVLVS

Regolare e distribuire energia pulita

°Caleon Thermostat - Wi-Fi

Elegant chrono-thermostat with TFT capacitive touch panel. Wi-Fi N 2.4 Ghz connection for remote control by °Caleon app.

Product file

ModvFresh Basic

Compact heat exchange unit to deliver fresh domestic hot water (DHW).

Product file

DomvS Clima

Control unit for manifolds of heating and cooling radiant panels up to 200 m2. Fixed point thermostatic mixer or motorized rotary mixing valve. LCD room control unit.

Product file

726 - Basic Series

Anti-scald thermostatic mixing valve for medium and small applications. Compact size. Available Kvs: 1.5, 1.8 and 3.4 (news from October 2019).

Product file

1610

Full bore 2-way zone ball valve, with bidirectional actuator with quick connection. Dimensions from 1/2" DN15 to 1"1/4 DN32.

Product file

Mixing kit for ModvFresh Basic

35÷60°C thermostatic mixing kit designed for ModvFresh Basic, with anti-scald thermostatic mixing valve for small applications.

Product file

Logico

Multifunctional compact hydraulic module for the management of a direct circuit, a mixed circuit and the production of domestic hot water (DHW)

Product file

MCCS 3 745-3

Anti-condensing pump unit with electronic control
Employment:

The anti-condensing pump unit allows to connect directly the solid fuel heating source to the heating system or to the buffer tank without any additional device.
As a matter of fact the pump unit includes into a compact and nice insulation box the circulating pump, the mixing valve operated by electronic control, the on/off natural circulation clapet valve, the isolating valves and thermometers.
It automatically adjusts the return water temperature to the heating source at the temperature set on the servomotor.

The device keeps the heating source at a high temperature level (always higher than the condensation one) in every possible condition of use, so avoiding deposits both into the boiler and into the chimney flue, in this way improving the efficiency and the life of it. Therefore also corrosion problems of the heating source or dangerous fires of the chimney are avoided.
 
Technical features:

Anti-condensing recycling and distribution pump unit with electronic control of the return temperature to the solid fuel heating sources.
Cast brass body CB753S. Yellow brass execution.
  • Synchronous high efficiency Wilo Yonos Para RS/7,5-RKC circulating pump with progressive speed control.
  • Maximum working pressure: 6 bar.
  • Maximum temperature: 100°C.
  • Mixing valve with fixed temperature servomotor.
  • Adjustable diverting temperature from 0 up to 99°C.
  • PT1000 contact temperature sensor with fixing kit to be mounted on the pipe.
  • Natural circulation clapet valve: with external control, it can be set on or off according to the type of installation.
  • Temperature thermometers: 0-120°C.
Diverting temperature: adjustable from 0 up to 99°C.
Available external connections: 1” and 1”1/4  female, 28 mm for copper pipe.


PED 97/23/EC, art. 3.3
FIELD OF UTILIZATION:
For power up to 90 kW (with Δt 30 K) and maximum flow 2600 l/h.
For an accurate measuring or for higher flows, please refer to the curves.
Diverting
temperature:

adjustable from
0 up to 99°C.
Synchronous circulating pump:
Wilo Yonos Para RS/7,5-RKC (C8)



A version with 3 points servomotor is also available (code with final part ...-M21). In this case an electronic external controller is required.
Installation:

The anti-condensing recycling pump unit can be placed on both sides of the heating source, following these directions:
  • On the return pipe to the boiler in mixing mode, following the flow directions shown on the body.
  • In vertical position (horizontal circulating pump axis) to allow the hydraulic working of the natural circulation clapet valve.
In order to optimize the anti-condensing control, we recommend the installation of the component on the return way to the boiler.
 

Installation placed on the right of the heating source.

Installation placed on the left of the heating source.
 
 
Working mode:

The schemes shown below represent the different working phases of the anti-condensing pump unit.
Please note that: the pictures have to be considered just as an indication and they have no completeness pretention.



  (1) Starting of the installation (boiler warming up)

After the starting of the boiler, the mixing valve is fully closed towards the user’s return (gate A) and this condition remains until the fluid, warmed up by the heating source, gets the temperature set on the servomotor. During this step the fluid sent by the boiler fully recycles through the by-pass (gate B) and the boiler temperature rises very quickly.

  (2) Loading of the installation (tank warming up)

At the achievement of the diverting temperature (f.i. 60°C) the users’ return way (gate A) proportionally starts to open, meanwhile the by-pass (gate B) is going to be closed. The boiler temperature slowly rises giving energy to the user, but in any case the return temperature will not decrease anymore below the diverting temperature (f.i. 60°C).

  (3) Working installation

Starting from the condition of point 2, the supply temperature progressively rises up to the full opening of the mixing valve (gate A) and up to the corresponding shutting of  by-pass (gate B). It is possible to change the parameters of the servomotor to make more or less reactive the shift from closed to open mixing valve, according to the features of the installation and to the power of the heating source. Now the installation is on working and the supply fluid temperature can rise up to the set value.
  (4) Natural circulation

The natural circulation of fluid through the clapet valve starts as soon as the circulating pump stops and the remaining energy of the heating source is transferred to the water tank.
This function starts as a security device, when the pump stops due to blackout or failure, so avoiding that the temperature of the heating source can reach high levels of danger.
To turn on the natural circulation function please turn the control screw anti-clockwise. You can lock the clapet valve any time, turning the screw clockwise (this operation has to be done when the pump is working).
Lead screw    


Checking of working conditions

Click on the drawing to download pdf version in high-res
To show a relistic example, we take into account the following starting values:
  • Heating source power: 28 kW
  • Δt value: 20 K
The side diagram shows that the flow rate of 1,2 m3/h is a consequence of these choises.

In the diagram of the circulating pumps, at the bottom of the page, it is possible to cross geometrically this flow rate value with the curve of the sected speed. In correspondance with this crossing it is possible to read on the scale on the left side the lifting power developped by the pump in these conditions.
The Yonos Para RS/7,5 pump develops a 3,1 mH2O lifting power in correspondence of curve II.
In the specific case of our example, if this lifting power is not enough for the installation needs, a higher speed of the pump should be selected: Curve III.


Hydraulic performances

The hydraulic performances of the pump unit (A towards AB) have been tested at Wilo laboratories. These performances are substantially the same even in case of recycling flow (B towards AB).

Wilo Yonos Para
RS/7,5-RKC
Consumption: 3-76 W
Maximum speed (III)
Medium speed (II)
Minimum speed (I)
Progressive setting
of the speed.
 



Click on the drawing to download pdf version in high-res

Direct supply to the distributor: up to 45 kW (with ∆t 20 K) and maximum
flow rate of 1950 l/h. Lifting power: 4 mH2O
With buffer tank: fino a 90 kW (con ∆t 30 K) and maximum flow rate of 2600 l/h. Lifting power: 2 mH2O

Test reports in pdf format, made directly by the Wilo laboratory are available:
they gather the results of performance analysis and verification of noise.

Dimensional specifications:





Specifications Dimensions
1"
1"1/4
28 mm
A
B
C
D
E
F
G
H

Weight [g]
259
222
162
124
13
196
187
79
4.300
259
222
162
124
14
200
189
81
4.350
259
222
162
124
18
200
189
81
4.350

Code 1”:  204MCCS-C8-(ACC/M21)
Code 1”1/4205MCCS-C8-(ACC/M21)
Code 28 mm:  228MCCS-C8-(ACC/M21)