BRV Bonetti Rubinetterie Valduggia S.r.l.

MODVLVS

Regolare e distribuire energia pulita

1610

Full bore 2-way zone ball valve, with bidirectional actuator with quick connection. Dimensions from 1/2" DN15 to 1"1/4 DN32.

Product file

°Caleon Thermostat - Wi-Fi

Elegant chrono-thermostat with TFT capacitive touch panel. Wi-Fi N 2.4 Ghz connection for remote control by °Caleon app.

Product file

DomvS Clima

Control unit for manifolds of heating and cooling radiant panels up to 200 m2. Fixed point thermostatic mixer or motorized rotary mixing valve. LCD room control unit.

Product file

Mixing kit for ModvFresh Basic

35÷60°C thermostatic mixing kit designed for ModvFresh Basic, with anti-scald thermostatic mixing valve for small applications.

Product file

ModvFresh Basic

Compact heat exchange unit to deliver fresh domestic hot water (DHW).

Product file

Logico

Multifunctional compact hydraulic module for the management of a direct circuit, a mixed circuit and the production of domestic hot water (DHW)

Product file

726 - Basic Series

Anti-scald thermostatic mixing valve for medium and small applications. Compact size. Available Kvs: 1.5, 1.8 and 3.4 (news from October 2019).

Product file

Solo 1 ACS

Pump unit to load one HDW buffer tank
Compact fully assembled pump unit to supply the heat produced by a solar thermal installation with High Flow or Low Flow operating mode. Suitable to be used with 1 buffer storage tank for HDW.
It is supplied fully insulated and pre-wired, with pre-programmed controller and it allows a fast and easy mounting.

The unit consists of:

Primary solar circuit:
  • Flowmeter with flow regulation with filling and draining valves. Alternatively a digital flowmeter is also available.
  • High efficiency solar synchronous pump.
  • 3-way return ball valve with check valve 10 mbar supplied with in-handle thermometer.
  • Security unit 6 bar with manometer ø50 mm 0-10 bar with 3/4” male connection to the expansion vessel. End of drain side: 3/4” F.
  • Supply ball valve with check valve 10 mbar supplied with in-handle thermometer.
  • Air vent made of brass with automatic vent valve and isolating valve.
Heat exchanger:
  • Weld-braised plates heat exchanger made of stainless steel AISI 316 suitable for several powers.
Secondary circuit (INOX AISI 316 pipes):
  • TÜV security valve 6 bar, 50 kW, for drinking water. End of drain side: 3/4” F.  Other pressures available on demand.
  • Asynchronous circulating pump for HDW.

EPP insulation box (Measurements: 576x585x190 mm).
A special back plate fixes the unit to the insulation box and it allows a quick fitting to the wall.


PN 10. Constant temperature on the solar circuit 120°C;
(short time: 160°C for 20 s).
Maximum temperature on the secondary circuit 110°C.
Available external connections:

  • 1” Male for solar circuit.
  • 3/4” Male pipe union for the secondary circuit.
FIELD OF UTILIZATION:
For power up to 35 kW. One buffer storage tank for HDW.
Kvs value: see the diagram here below.

A special ball valves kit, available upon request (to be ordered) completes the unit.

Typical curves of solar circuit
Typical curves of secondary circuit (HDW)
Click on the pictures to download the pdf version


ModvSol Solo 1 ACS

Heat supply pump unit to load one hot domestic water HDW buffer tank. Suitable for a solar collectors surface up to 70 m2.

The pump unit, as shown in the illustrative scheme at side, gets the heat from the primary circuit (solar) and brings it to the heat exchanger. Then the thermic energy is tranferred to the secondary circuit, and in the specific case of ModvSol Solo 1 ACS, it feeds directly only the hot domestic water tank.





NOTE: The schemes are incomplete and to be considered just as an indication.

 

(A) -
(B) -

(C) -

(D) -
Solar collectors
Circulating pump of primary circuit
Circulating pump of secondary circuit
Heat exchanger
(E) -

(F) -
(G) -
(H) -
Mechanical flowmeter
or digital VFS sensor
Buffer tank
emperature sensors
Users' HDW


Solo 1 ACS High Flow

Article code                  
Tapping surface
of solar collectors
Delivered
thermic power
Δt Primary circuit
circulating pump
Secondary circuit
circulating pump
031230-24-(28/40)-LT 30 m2 15 kW 10 K Wilo Stratos
Para 25/1-7
Wilo Star
Z 25/6
031230-40-(38/40)-LT 46 m2 23 kW 10 K Wilo Stratos
Para 25/1-8
Wilo Star
Z 25/6


Solo 1 ACS Low Flow

Article code Tapping surface
of solar collectors
Delivered
thermic power
Δt Primary circuit
circulating pump
Secondary circuit
circulating pump
031230-24-(28/40)-LT 50 m2 25 kW 25 K Wilo Stratos
Para 25/1-7
Wilo Star
Z 25/6
031230-40-(38/40)-LT 70 m2 35 kW 25 K Wilo Stratos
Para 25/1-8
Wilo Star
Z 25/6
It is possible to select two versions for each model indicated in the above table: one with mechanical flowmeter, another with digital VFS sensor.

Models with mechanical flowmeter:
the flowmeter has a measuring range of 8-28 or 8-38 l/m, default value according to the specific model selected. Product codes of these models have respectively the options 28 or 38. For instance: Solo 1 ACS, High Flow, with an exchanged power of 23 kW: code 031230-40-38-LT.

Models with digital VFS sensor:
all these models have the VFS sensor with a measuring range of 2-40 l/min. Product code of these models have the option 40. For instance: Solo 1 ACS, High Flow, with an exchanged power of 23 kW: code 031230-40-40-LT.